SARS CoV 2 Nucleocapsid Antibody, IgG

General Information

Lab Name
SARS CoV 2 Nucleocapsid Antibody, IgG
Lab Code
NCVIGG
Epic Name
SARS-CoV-2 Nucleocapsid Antibody, IgG
Description

The Abbott Architect SARS-CoV-2 IgG assay, run under an emergency use authorization from the FDA, is a qualitative test designed to detect IgG antibodies to the nucleocapsid protein of SARS-CoV-2 in serum and plasma from patients who are suspected of past coronavirus disease (COVID-19) or in serum and plasma of subjects that may have been infected by SARS-CoV-2.

Reactive (Positive) results may be due to past or present infection with SARS-CoV-2. Results from antibody testing should not be used as the sole basis to diagnose or exclude SARS-CoV-2 infection or to inform infection status.

Nonreactive (Negative) results do not rule out SARS-CoV-2 infection, particularly in those who have been in contact with the virus. Follow-up testing with a molecular diagnostic should be considered to rule out infection in these individuals. Results from antibody testing should not be used as the sole basis to diagnose or exclude SARS-CoV-2 infection or to inform infection status.

For Batteries containing NCVIGG refer to:

SARS-CoV-2 Antibodies (NCVIGG, NCVIGQ)[NCVIGB], The qualitative detection of anti-Nucleocapsid IgG (NCVIGG) and the quantitative detection of anti-Spike IgG (NCVIGQ) antibodies.

For all questions, contact Client Support Services (available 24/7):

Phone: (206) 520-4600 or (800) 713-5198
Fax: (206) 520-4903
Email: commserv@uw.edu

The test order requisition is available online.

Synonyms
2019-nCoV, antibody, corona, coronavirus, COVID, COVID-19, COVID19, IgG, nCoV, SARS, SARS-CoV-2
Components

Interpretation

Guidelines
Method

Chemiluminesence

Reference Range
See individual components
Ref. Range Notes

See individual components

Ordering & Collection

Specimen Type
Blood
Collection
  • Preferred: 5 mL blood in GOLD SST tube.
  • Also Acceptable: Orange RST, pearl PPT, serum from red top, plasma from EDTA tube.
Forms & Requisitions

UW Medicine Locations

Place order in ORCA, using "COVID-19 Antibody (IgG)".

For UWMC-Northwest ED/inpatients, place a Lab Undefined order in Soarian or PulseCheck for "NCVIGG: COVID-19 IgG."

Other Locations (eg, reference laboratory client)

Send all samples with the requisition available here (form is a fillable pdf - please download and enter information before printing)

Handling Instructions
  • Spin within 24 hours and prior to shipment.
  • Sample is stable for 7 days at 2-8°C once separated from a clot or red blood cells, or in a gel separator tube.
  • If testing will be delayed more than 7 days store at -20°C or colder.

Send Specimens to:

UW Medicine
Department of Laboratory Medicine
Virology- Central Testing Lab
1602 Raymond Ave SW
Renton, WA 98057-3356
Tel: (206) 658-6656 opt 4

Quantity
Requested: entire sample
Minimum: 0.5 mL serum/plasma

Processing

Receiving Instructions

Centrifuge GOLD SST tube and route to Virology Central Lab (Renton).

Centrifuge RED TOP or EDTA tube and aliquot serum/plasma into plastic aliquot tube. Route to Virology Central Lab (Renton).

Stability: Sample stable off the clot, red blood cells, or separator gel for 7 days at 2-8°C. If testing will be delayed more than 7 days store at -20°C or colder.

Misc Sendout

Performance

Lab Department
Central Lab Virology(RVIR)
Frequency
Mondays and Fridays, with results available on the same day.
Available STAT?
No
Performing Location(s)
CL Virology, Renton
206-685-6656

1602 Raymond Ave SW

Renton, WA 98057-3356

206-685-6656 opt 4

Billing & Coding

CPT Codes
86769
LOINC
94504-8
Regulatory Category
Laboratory-developed test
Interfaced Order Code
UOW3785
Billing Comments

List price: $42