Rapid Maximum Amplitude (MA)
General Information
- Lab Name
- Rapid Maximum Amplitude (MA)
- Lab Code
- CRTMA
- Description
The TEG 6S instrument assesses blood viscoelastic properties using resonance technology, exposing the blood to a fixed vibration frequency range upon adding calcium and exposure to kaolin with tissue factor. The clotting process is accelerated in this test by the addition of high concentration kaolin and tissue factor. The maximum amplitude achieved under these conditions is measured and provides information regarding clot strength.
- Synonyms
- MA Rapid, Rapid TEG, Rapid TEG6S
- Components
Interpretation
- Method
TEG6S
- Reference Range
-
Units: mm
Female Male Age Range Age Range 0- 52.0-70.0 0- 52.0-70.0 Effective date: 06/01/2024
Ordering & Collection
- Specimen Type
- Whole Blood from Blue top tube
- Collection
-
3 mL Blue (Citrate) Tube. Send separate tube for this test done on whole blood.
- Handling Instructions
The lab must receive this sample within 3 hours of collection. Samples can go to the OR (Satellite) lab when that is open and to the main lab when the OR (Satellite) lab is closed.
Processing
- Receiving Instructions
Send samples to OR (Satellite) lab when open and main lab when OR (Satellite) lab is closed.
- Misc Sendout
Performance
- Lab Department
- Coagulation(COAG)
- Frequency
- Daily
- Available STAT?
- Yes
- Performing Location(s)
-
UW-MT Coagulation
206-520-4600Clinical Lab, Room NW220,
University of Washington Medical Center,
1959 NE Pacific street, Seattle, WA 98195
Billing & Coding
- LOINC
- 97005-3