HBV Surface Antigen (HBsAg) Quantitative, Monitoring
General Information
- Lab Name
- HBV Surface Antigen (HBsAg) Quantitative, Monitoring
- Lab Code
- HBSAGQ
- Epic Name
- HBV Surface Antigen (HBsAg) Quantitative, Monitoring
- Description
For monitoring the progression of chronic hepatitis B and their response to antiviral therapy. This Quantitative detection of Hepatitis B virus Surface Antigen (HBSAg) in human sera incorporates the modified FDA approved ARCHITECT HBsAg test one-step chemiluminescent microparticle immunoassay (CMIA).
The performance characteristics of the test were determined by the University of Washington Department of Laboratory Medicine and Pathology. The modified version has not been cleared or approved by the US Food and Drug Administration.
Note: This test should only be ordered in individuals with chronic Hepatitis B, confirmed positive for HBV Surface Antigen (HBSAg).
For initial HBV diagnosis, see Hepatitis B Surface Antigen (HBsAg) with reflex to PCR for REACTIVE [HBSAG] or Hepatitis B Surface Antigen without PCR reflex for REACTIVE [HBSAGX].
- Synonyms
- HBSAG, HBV
- Components
-
Code Name HBSAQR HBV Surface Antigen Quantitative Result HBSAQI HBV Surface Antigen Quantitative Interpretation
Interpretation
- Guidelines
- Method
Chemiluminescence Immunoassay
- Reference Range
- See individual components
Ordering & Collection
- Specimen Type
- Peripheral Blood
- Collection
-
Preferred: 5 mL blood in GOLD SST tube
Also acceptable: 5 mL blood in ORANGE RST or RED TOP.
- Quantity
-
Requested: 1.0 mL serum
Minimum: 0.5 mL serum
Processing
- Receiving Instructions
GOLD SST tube: Specimens may be stored on or off the clot, red blood cells, or separator gel for up to 3 days at room temperature (15-30°C) or up to 7 days at 2-8°C. If testing will be delayed more than 3 days for specimens stored at room temperature or more than 7 days for specimens stored at 2-8°C, remove serum from the clot, red blood cells, or separator gel and store at -20°C or colder. Avoid more than three freeze/thaw cycles.
Unacceptable samples: Cord blood, neonatal specimens, cadaver specimens, heat-inactivated specimens, or body fluids such as saliva, urine, amniotic fluid, or pleural fluid. Specimens with obvious microbial contamination or that are grossly hemolyzed.
- Misc Sendout
Performance
- Lab Department
- Central Lab Virology(RVIR)
- Frequency
- Performed twice a week.
- Available STAT?
- No
- Performing Location(s)
-
CL Division of Infectious Disease Diagnostics (DIDD) - Virology 1601 Lind Ave SW
Renton, WA 98057Phone: 206-685-6656 option 8
Hours of Operation:
Mon–Fri: 7:00 AM–7:00 PM
Sat: 9:00 AM–4:00 PM
Billing & Coding
- CPT Codes
- 87467
- Interfaced Order Code
- UOW6628