Inner Ear Antigen by Western Blot
General Information
- Lab Name
- Inner Ear (Cochlear) Antigen by Western Blot (Sendout)
- Lab Code
- REARWB
- Epic Name
- Inner Ear (Cochlear) Ag by WB
- Synonyms
- anti 68kD ab, Autoantibody Inner Ear-WB, Cochlear Antibody, Heat Shock Protein, HSP 70, HSP-70
- Components
-
Code Name REARWR Inner Ear Antigen: Anti 68 kD Antibody
Interpretation
- Method
- Line Blot
- Reference Range
- See individual components
Ordering & Collection
- Specimen Type
- Blood
- Collection
- 9 mL blood in RED TOP tube or SST
- Quantity
-
Requested: 3 mL serum
Minimum: 2 mL serum
Processing
- Receiving Instructions
- Centrifuge & separate serum into plastic vial. Freeze serum
Sendouts, order MAYO test code F68KDStability: Frozen: 365 days; Refrigerated: 5 days; Ambient: 48 hours
- Misc Sendout
Performance
- Lab Department
- Sendouts Mayo Lab (FZ)(MAFZ)
- Frequency
- Available STAT?
- NO
- Performing Location(s)
-
HMC Sendout UW-MT Sendout - Other Locations/Notes
- MAYOMAYO forwards to IMMUNE Diagnostics (IMMCO) 60 Pineview Dr, Buffalo, NY 142281-800-533-1710
Billing & Coding
- CPT Codes
- 84182
- LOINC
- 43597-4
- Interfaced Order Code
- UOW2309