Peanut IgE Component Panel (Sendout)

General Information

Lab Name
Peanut IgE Component Panel (Sendout)
Lab Code
RPEANT
Epic Name
(not orderable in Epic)
External Test Id
2007211
Description

Test Information: This panel includes Peanut IgE, Severe Peanut Ara h 1, Severe Peanut Ara h 1, Severe Peanut Ara h 3, Severe Peanut Ara h 9, Mild Peanut Ara h 8, and Severe Peanut Ara h 6.

    Ordering Note: Non-orderable battery included in package Peanut IgE Component Panel (Sendout) [RPICAP].

    Synonyms
    2007211, Ara h 1, Ara h 2, Ara h 3, Ara h 6, Ara h 8, Ara h 9, Peanut Component Allergy Profile, Peanut IgE Components
    Components

    Interpretation

    Method

    Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

    Reference Range
    See individual components
    Ref. Range Notes
    Reporting Range Probability of IgE Mediated Clinical Reaction Class Scoring
    <0.10 No significant level detected 0
    0.10 - 0.34 Clinical relevance undetermined 0/1
    0.35 - 0.70 Low 1
    0.71 - 3.50 Moderate 2
    3.51 - 17.50 High 3
    17.51 - 50.00 Very high 4
    50.01 - 100.00 Very high 5
    >100.00 Very high 6

    Interpretive Data: Allergen results of 0.10-0.34 kU/L for whole peanut are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

    Ordering & Collection

    Specimen Type
    Blood
    Collection

    Collect 3 mL blood in GOLD SST or RED TOP tube

    Quantity
    Requested: 1 mL serum + 1 mL serum for UW429
    Minimum: 0.5 mL serum

    Processing

    Receiving Instructions

    Centrifuge sample and aliquot 1 mL serum each into two separate plastic vials. If sample volume is low, prioritize the sendout test (RPEANT).

    • RPEANT: Place serum aliquot in the refrigerated ARUP Sendouts rack.
    • UW429: Palce serum aliquot in the frozen Immunology rack.

    Sendouts:

    • Order ARUP Test: 2007211
    • Interfaced: Yes [Interface: 602; Department: ARPR]

    Stability: Refrigerated (preferred): 2 weeks; Frozen: 1 year; Ambient: 48 hours.

    Unacceptable Conditions: Hemolyzed, icteric, or lipemic specimens.

    Misc Sendout

    Performance

    Lab Department
    Sendouts ARUP Lab (RF)(ARPR)
    Frequency
    Performed: Sunday through Saturday. Reported: 1-3 days from sample receipt at ARUP Laboratories.
    Available STAT?
    No
    Performing Location(s)
    Sendout ARUP Laboratories, Inc.
    800-522-2787

    500 Chipeta Way
    Salt Lake City, UT 84108

    Billing & Coding

    CPT Codes
    86003, 86008x6
    LOINC
    18716-1