Glucose, Whole Blood

General Information

Lab Name
Glucose, WBLD
Lab Code
WGLU
Epic Name
Glucose, Whole Blood
Description

Fasting glucose of 126 mg/dL or greater or random glucose >200 mg/dL is diagnostic of diabetes mellitus. Reference: Diabetes Care 2013 36: S11-S66. It can be found on the following website: Diabetes Care

Components

Interpretation

Method

Electrochemistry

Reference Range
Units: mg/dL
Female Male
AgeRange AgeRange
0-29d62-125 0-29d62-125
1m-62-125 1m-62-125

Effective date: 05/19/2014

Ref. Range Notes

Upper limit is based on ADA guidelines for diagnosis of diabetes using a fasting glucose measurement. See above for website.

Ordering & Collection

Specimen Type
Blood
Collection

Arterial or Venous blood collected in a balanced heparinized syringe such as the Radiometer PicoTM or Smiths Portex Pro-Vent syringes. Pediatric draw: Arterial or Venous blood collected into a 1 mL balanced heparinized syringe Also acceptable: GREEN TOP, LIME GREEN TOP unspun Unacceptable: any microtainer tube

Handling Instructions

Needles must be removed from syringes and replaced with caps before sending to the lab. No air bubbles. Transport to Lab immediately in tube system.

Quantity
Requested: Full Syringe whole blood
Minimum: 0.20 mL

Processing

Receiving Instructions

Login as STAT and take to Blood Gas Bench Immediately

Misc Sendout

Performance

Lab Department
Chemistry, Whole Blood(CHW)
Frequency
Daily
Available STAT?
Yes
Performing Location(s)
HMC Chemistry, Automated
206-520-4600

325 9th Ave, Rm # GWH-47, Seattle, WA 98104-2420

UW-NW Main Lab
206-668-1344

UW Medical Center – Northwest
1550 N 115th Street, A200
Seattle, WA 98133

UW-MT Chemistry, Blood Gas
206-520-4600

Clinical Lab, Room NW220,
University of Washington Medical Center,
1959 NE Pacific street, Seattle, WA 98195

Billing & Coding

CPT Codes
82947
LOINC
2339-0